All manuals and user guides at all-guides.com
■ Gravity flow cup connection piece
[1-15]
Spray gun body
■ Gun body [1-9]
■ Round fan control [1-14] fixed to ideal
value, not adjustable
■ Flat fan control [1-6] with scale
washer [1-5]
■ Material flow control [1-2] with scale
on gun body [1-13] and scale ring
[1-3]
■ Fastening bolt [1-1]
■ Control air connection [1-11]
■ Spraying air connection [1-12]
8.
Assembly
Attention!
Loose screws can cause damage
to parts or result in malfunctions.
→ Tighten all screws by hand and
check that they are screwed tight.
Note!
All automatic guns have integrat-
ed pre-/post-air control.
The automatic gun is fixed in the
spraying system with a fastening
bolt. The air supply then has to
be connected. The air supply con-
nection elements are not included
in the scope of supply and can be
ordered on request.
SATA LAB Automatic Gun Operating Instructions
8.1. Mounting with fastening
Screw fastening bolt [3-1] in fasten-
ing thread [3-2]. Secure with Loctite
270.
■ Use fastening bolt to fix the automatic
gun to the fastening system of the
spraying system.
■ Connect control air to the control air
connection (ST) [1-11] of the auto-
matic gun.
■ Connect spraying air to the spraying
air connection (SP) [1-12] of the
automatic gun.
9.
Operation
Loose screws can cause damage
to parts or result in malfunctions.
→ Tighten all screws by hand and
check that they are screwed tight.
9.1. First use
The automatic gun is supplied fully
assembled and ready for operation.
After unpacking, check:
■ Automatic gun damaged.
■ Scope of supply complete (see
chapter 5).
Using soiled compressed air can
cause malfunctions.
→ Use clean compressed air. For
example with SATA filter 444
(Art. No. 92296).
■ Check that all screws are screwed
bolt
Attention!
Attention!
EN