11.2.5 Technical data of DMX pumps with VFD

General technical data
Observe the values stated on the nameplates and in the installation and operating instruc-
tions.
For technical data, ambient conditions and operating conditions, see section Technical data.
Electrical data of the VFD
Parameter
Type of current
Mains voltage
Mains frequency
VFD power
Motor power
For electrical data, such as current consumption, see the nameplates of the motor and the VFD.

11.2.5.1 Dimensional sketch of DMX pumps with VFD

For all other dimensions, see section "Dimensional sketch".
Pump type
all
Related information
• 9.5.1 Dimensional sketch
Value
1 AC (single-phase)
200-240 V ± 10 %
47-63 Hz
0.25 kW
0.18 kW
x
w
[mm]
[mm]
376
276
DMX 221 | | 61
y
z
[mm]
[mm]
128
97