Use - SATA minijet 1000 K RP Instrucciones De Servicio

Ocultar thumbs Ver también para minijet 1000 K RP:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 125
Operating Instructions SATAminijet 1000 K RP, SATAminijet 1000 H RP
All manuals and user guides at all-guides.com
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!

7. Use

• Use only solvent-resistant, antistatic, undamaged and technically flaw-
less compressed air hoses with a permanent pressure resistance of
minimum 10 bar / 145 psi, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use of a compressed air connection G 1/4 a or of a fitting SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Clean compressed air, i.e. with SATA filter 100, Art. No. 148247,
outside the spray booth or SATA filter 484, Art. No. 92320 in-
side the spray booth
• Use an air hose with minimum 6 mm inner diameter (see warnings),
e.g. Art. No. 53090.
51. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been
tightened firmly. Tighten fluid tip [2-1] firmly by hand (12 Nm) accord-
ing to [7-4]. Check if locking screw [2-5] has been firmly tightened
according to [10-1]. Tighten, if necessary.
52. Adjust air cap: vertical spray fan [2-6], horizontal spray fan [2-7].
3. With SATAminijet 1000 K RP: Connect the material hose of the tank
or pump to the spray gun material connection.
With SATAminijet 1000 H RP: Connect the suction cup, e.g. SATA
RPS 0.3 l cup w/ RPS adapter, to the material connection [1-3]. When
using a RPS 0.3 l suction cup set, first locate the plastic insert into
the neck of the RPS cup lid from above before pressing in the pick-up
Danger! Risk of explosion!
Danger! Risk of explosion!
Information!
US
419

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Minijet 1000 h rp

Tabla de contenido