Mark holes
Select the vent option that your installation will require and proceed to
that section:
Outside top exhaust
Use the diagram or the hood as a template and mark the locations on
the cabinet for ductwork, electrical wiring and keyhole screw slots.
"
1
"
13
11
10
"
37
32
16
64
(1 cm)
(4.3 cm)
(26.86 cm)
Cabinet bottom side
4
7
32
(10.7cm)
7
"
3
32
(18
cm)
Ø
"
55
64
(2.2cm)
system hole
2
"
19
32
(6.6
cm)
Wiring access knockout
1
"
47
64
(4.4 cm)
(cabinet bottom side)
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2 wood shims the
width of the trim and attach them to the cabinet bottom recess on
both sides.
Wood shims
Outside rear exhaust
(Horizontal duct Ø 6" (15.2 cm))
Use the diagram or the hood as a template and mark the locations
on the wall for ductwork, electrical wiring and keyhole screw slots.
TOP OF THE
6
"
57
64
HOOD
(17.5cm)
1
"
27
64
(3.6cm)
4
"
27
32
(12.3cm)
4
(10.7cm)
4
"
61
64
"
9
32
(12.6cm)
(0.7cm)
BOTTOM OF THE
HOOD
1. Remove the grease filters.
2. Remove the blower mounting screws. Put the screws in a
safe place in order to use them again.
Cabinet
front side
Mounting
"
4
"
7
32
screws (4)
(10.7cm)
Vent
6
"
17
Vent
64
shims
(15.9 cm)
CENTER
"
35
64
LINE
(1.4
cm)
6
"
3
"
1
"
57
25
11
64
32
16
(17.5cm)
(9.6cm)
(4.3cm)
1
" (4 cm)
37
64
6
"
"
17
55
64
64
(15.9cm)
(2.2cm)
"
4
"
7
7
32
32
(10.7cm)
3. Set free the two blower springs from the top of the range
hood housing.
4. Flip the blower base to the rear face of the range hood.
5. Insert the two blower springs to the top of the range
hoodhousing, Secure it with the four mounting screws
previously released.

Mounting the Hood

1
"
Wall Installation
1
16
(2.7cm)
Install framing for hood support
1. Mark the screw hole locations indicated in the "Outside rear
exhaust" figure.
2. If drywall is present, cut away enough drywall to expose
2 vertical studs at the indicated holes location. Install two
horizontal supports between two wall studs at the bottom and
upper mounting holes installation location.
3. The horizontal support must be flush with the room side of the
studs. Use cleats behind both sides of the support to secure
wall studs.
4. Reinstall drywall and refinish.
6
IMPORTANT: Framing must be capable of
supporting 100 lbs.
View from rear
Cleats
Mounting
Support
Centerline of
Installation