Mounting the hood
1.
Install transition on top of hood (if removed for shipping) with
2 - 3.5 x 9.5 mm sheet metal screws.
A. Vent transition
B. 3.5 x 9.5 mm screw
WARNING
2 people are required to lift and position the hood
onto the mounting screws.
■
Place the template on the wall along the horizontal line, make sure
the template is leveled and centered with the centerline.
■
Mark "upper" screw holes locations in the wall
IMPORTANT: Check to be sure that hole locations are leveled and
correctly centered bye the vertical centerline.
■
Drive "upper" wood screws by hand. Leave ¼" of distance between
the screw head and the wall.
¼˝
(6.4mm)
■
Remove the grease filter and mount the hood onto the "upper screws".
B
A
■ Mark "lower" wood screw holes locations in wall using a pencil.
■
Remove the hood.
■
Drive the "lower" wood screws, by hand. Remove screws.
■
Mount the hood onto the "upper" wood screws, by hand.
■
Drive and tighten the "lower" wood screws, by hand.
A
B
A. 5 x 45 mm screw
B. Mounting slots
Electrical Connection
WARNING
Electrical Shock Hazard
Warning: Turn off the power circuit at the service
panel before wiring this unit.
120 VAC, 15 or 20 Amp circuit required.
ELECTRICAL GROUNDING INSTRUCTIONS
THIS APPLIANCE IS FITTED
BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES
TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE
CONNECTED TO THE GROUNDING WIRE IN YOUR HOME ELEC-
TRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE
CUT OR REMOVED.
Failure to do so can result in death or electrical shock.
6
A
WITH AN ELECTRICAL JUNCTION