Operating manual
WELDING FUMES AND GAS
Fumes, gases and dusts emitted by welding are harmful to health. It is mandatory to ensure adequate
ventilation, and an additional air supply may be required. An air-fed mask could be a solution in situa-
tions where there is inadequate ventilation.
Check the extraction system's performance against the relevant safety standards.
Caution : Welding in confined spaces requires safety monitoring from a safe distance. In addition, the welding of certain
materials containing lead, cadmium, zinc, mercury or beryllium can be very harmful. also remove any grease on the
workpieces before welding.
Cylinders should be stored in open or well-ventilated areas. They should be stored in an upright position and kept on a
stand or trolley.
Welding should not be carried out near grease or paint.
FIRE AND EXPLOSION HAZARDS
Fully protect the welding area, and ensure that flammable materials are kept at least 11 metres away.
Fire fighting equipment should be kept close to wherever the welding activities are being undertaken.
Be careful of spatter and sparks, even through cracks, as it can be the source of a fire or an explosion.
Keep people, flammable objects and pressurised containers at a safe distance.
Welding in closed containers or tubes is to be avoided. If the containers or tubes are open, they must be emptied of all
flammable or explosive materials (oil, fuel, residual gas...).
Grinding work must not be directed towards the source of the welding current or towards any flammable materials.
GAS CYLINDERS
Gas escaping from cylinders can cause suffocation if there is too high a concentration of it in the wel-
ding area (ensure good ventilation).
The machine must be transported in complete safety: gas cylinders must be closed and the welding
power source turned off. They should be stored upright and supported to limit the risk of falling.
Close the cylinder between uses. Beware of temperature variations and exposure to the sun.
The cylinder must not come into contact with a flame, an electric arc, the gun, a ground clamp, or any
other source of heat or potential ignition.
Be sure to keep it away from electrical and welding circuits. Never weld a pressurised cylinder.
Be careful when opening the cylinder valve, keep your head away from the tap and ensure that the
gas used is suitable for the welding application.
ELECTRICAL SAFETY
The electrical network used must be earthed. Use the recommended fuse size from the rating plate.
A direct or indirect electric shock can cause a serious injury, or even death.
Do not touch any live part of the machine (inside or outside) when it is plugged in
(Guns, clamps, cables, electrodest because it is connected to the welding circuit.
Before opening the welding power source, disconnect it from the mains supply and wait 2 minutes. So that all the
capacitors are discharged.
Do not touch the gun or the electrode holder and the earth clamp at the same time.
Ensure that the cables are changed, if they are damaged, by qualified and authorised persnnel. Measure the cable cross-
section according to the intended application. Always use dry and in-fact clothing to insulate yourself from the welding
circuit. Wear insulated shoes in all working environments.
Warning ! Very hot surface. Risk of burns.
• The parts and pieces that have just been heated are hot and may cause burns when manipulated.
• Do not touch any hot parts with your hands.
• Wait for parts and equipment to cool before handling them.
• In the event of a burn, rinse with plenty of water and seek medical attention immediately.