Operating manual
LIST OF MESSAGES SHOWN AT THE BOTTOM OF THE WELDING DISPLAY
Message
Gun disconnected
Texas disconnected
Texas inverted
Ready
Movement only
Contact
Welding
Welding completed
Pre-Gas
Lost contact
Arc breakage
Lift gun
MAIN MENU
To access the Main Menu from Synergic and Manual modes, press the Menu/Enter button
Press the G+ and G- keys to move the section cursor. Make the selection by pressing the Menu/Validate button.
Main Menu
> Settings
Manual Mode
Configuration
Original manual
• "Settings" accesses the welding parameters (synergic or manual).
• "Manual Mode"/" Synergic Mode" changes the welding method of the machine
• "Configuration" accesses the advanced configuration of the machine
(language, gas management, information, etc.).
Press the back button
Description
No gun is connected to the unit.
The positive texas/dinse of the gun is not connected to
the power source.
(Synergic mode only) The polarity of the texas/dinse
connectors is reversed in relation to the polarity required
by the selected synergy.
The rest period is complete the unit is now available to
weld.
A trigger pull was detected without an insert being
brought into contact with the support plate. The gun then
does a mechanical movement only, the power source is
not switched on.
The product detects that an insert is in contact with the
support plate. If welding is done with gas shielding, the
solenoid valve opens for pre-gas.
Welding cycle in progress
The welding cycle is complete
Displayed when a trigger pull is detected before the
pre-gas time has elapsed (see section 7.4.3). For the
welding to take place, it is necessary to remain in the
right position (insert is always in contact with the support
sheet), and wait for the end of the pre-gas.
Displayed when contact between the insert and the sup-
port sheet is lost before the pre-gas time has elapsed.
An arc break occurred during the welding cycle.
Checking the weld will be necessary.
Displayed at the end of the welding cycle, if the gun is
still in position on the insert.
to return to the welding screen.