Operating manual
SYNERGIC MODE SETTINGS MENU
When operating in synergic mode, the setting menu is used for selecting the type of insert to be welded, its size, its
material and type of gas shielding.
In Synergic Mode, the settings are selected in order from top to bottom:
1 — Type of insert : studs, pins, rings.
2 — Size of the insert "EP. elec": Mx, Øx, etc.
3 — Material of the insert: Fe, FeCu, Al, etc.
4 — Type of welding protection: Ferrule, No gas, or with Gas
Note : When welding is to be done with gas shielding, the gas that is displayed is the one recommended to guarantee
the weld strength. In the event that this gas is not available, it may be necessary to switch to Manual Mode.
Press the G+ and G- keys to move the left cursor, and press the D+ and D- keys to change the values of each item.
Push the Menu/Enter button
Press the return button
MANUAL MODE SETTINGS MENU
When operating in manual mode, the setting menu allows individual adjustment of any welding-related parameter.
Manual Settings
1
2
Spring
Pressing the G+ and G- keys will highlight the selected parameter. Pressing the D+ and D- buttons changes the value
of this parameter.
1— Digital « flex » spring :
• Releases (ON) or locks (OFF) the drive shaft of the electrode holder when the insert comes into contact with the
support sheet.
• It is recommended to activate this function for all attachments except for pull rings.
2— Ignition :
• Adjustable from -2 to +8. Directly affects the set value of the power converter in the unit.
• At 0 (default value), the product provides optimal ignition without the risk of arc separation when the insert is lifted,
while limiting the short-circuit current.
Slightly increase the ignition in the case of repeated arcing failures.
3— Penetration and cleaning: Time adjustment (in milliseconds), and cleaning current.
4— Arc : Time adjustment (in milliseconds), and arc current.
5— Attachment:
• Adjustable from -2 to +8. Directly affects the set value of the power converter in the unit.
34
Original manual
Synergic Settings
> Stud
THK. elec.
Material
Gas
to confirm the synergy settings and return to the synergic welding screen.
to ignore the settings and return to the Main Menu.
> ON
3
M6
Fe
ArCo8%
6
&
7
5
4
GYSPOT COMBI ARCPULL