– The insulation of the pipes must be resistant to temperatures
until 155 °C.
Install the detergent tank
Figure 17 - Pos. 20
The tanks are to be installed in such a way that the lower level
mirror of the detergent should not be more than 1.5 m under the
machine floor and the upper level mirror should not be located
above the machine floor.
Exhaust system
– Each appliance must be connected to a separate chimney.
– The exhaust system must be designed according to the local
rules and regulations after consulting the concerned chimney
expert.
Water supply
Figure 17 - B and item 19
The water inlet is to be connected to the main water supply
using an appropriate water hose.
– The water supply must have a minimum output of 1300 l/h at
minimum 0.1 MPa.
– The water temperature must lie below 30 °C.
Electrical connection
Warning
The highest allowed net impedance at the electrical connection
point (refer to technical data) is not to be exceeded.
Note
Operating procedures create short term power sinkings. During
unfavorable net conditions other devices might be disturbed.
– For connection values, see technical data and type plate.
– The electrical connections must be done by an electrician ac-
cording to IEC 60364-1.
– Current-carrying parts, cables and appliances in the working
area must be installed in a defectless state and must be pro-
tected against water sprays.
To avoid accidents due to electrical faults we recommend the
use of sockets with a line-side current-limiting circuit breaker
(max. 30 mA nominal tripping current).
Firmly installed electrical connection
Establish the electrical connection.
A main switch that can be locked (figure 17 - item 6) is to be in-
stalled at a safe and easily accessible place to switch off the sta-
tionary high pressure cleaner.
The contact opening of the main switch must be minimum 3 mm.
Electrical connection with plug/ socket
Install Cekon plug on the connection cable of the appliance.
Insert Cekon plug into the socket.
To switch off the stationary high pressure cleaner, the Cekon
plug must be easily accessible so that it can be removed from the
mains.
The plug and coupling of the extension cable used must be wa-
tertight.
Always fully unroll electrical cables from the cable drum.
Initial startup
The device is set in the factory as a natural gas device to gas
type G 20 and as LPG device to G 31. While switching over
natural gas devices to G 25 or other natural gases (see type
plate) or the LPG device to G 30 or other LPGs (see type plate),
the natural gas exhaust values in case of natural gas devices
and the LPG exhaust values in case of LPG devices are to be
set according to the service information.
38
English
The enclosed empty type plate will be filled up with values of
the new gas type that is set and will be fixed on the right side of
the device in the address field. At the same time, the plate with
the G 20 (natural gas device) details or G 31 (LPG device) de-
tails fitted at the factory must be removed.
Check gas connection.
Warning
Risk of damage to the appliance on account of over-heating.
Connect the siphon to the boiler floor and fill water.
Fill the boiler via the chimney opening with 4 litres of water.
Before using for the first time, cut off the tip of the lid of the oil
tank on the water pump.
Measures to be taken before start-up
Figure 17 - Pos. 14
Connect the high pressure hose with the hand-spray gun and
the spray pipe and connect it to the high pressure outlet of the
appliance or the high pressure pipe network.
a
Figure 13
Fasten the nozzle mouth-piece (b) with the union nut (a) on
the spray pipe (d). Please ensure that the sealing ring (c) is
cleanly positioned in the nut.
Anti-calcification measures
b
c
a
Figure 14
Remove spring (c) from the lid support (b) of the softener tank
(a).
Fill the tank with Kaercher softener liquid RM 110 (Order no.
2.780-001).
Danger
Risk of electrical voltage! Setting may only be done by an electri-
cian.
Determining the hardness of tap water:
– through the public water supply works,
– using a hardness tester (order no. 6.768-004)
Remove the appliance cover.
b
c
d