5
Troubleshooting
Error
Air Guard not active
Unusually high O
content
2
No alarm despite exceeding of
the limit values defined in
DIN EN 12021
Flow rate too low for
measurement
The purging does not start.
Error on gas detector
or sensor, measured
value displayed on
touchscreen with #. The
compressed air supply cannot
be started or runs out.
The alarm threshold has been
exceeded.
The value has fallen below the
alarm threshold.
The full scale value has fallen
below the range limit.
The full scale value has
exceeded the range limit.
The value has exceeded or
fallen below the warning
threshold.
The UV lamp is being
checked.
The zero offset adjustment
failed.
Cause
The power supply is not present. Connect the power supply.
The circuit breakers tripped.
The hose behind the O
sensor is
2
kinked.
The limit values defined in the
Air Guard were changed.
Dosage system is clogged.
The hose is kinked, damaged or
the joint has loosened.
The inlet pressure is too low.
Leakage in the PID 5000
The gassing adapter on the gas
detector is incorrectly fitted.
No user logged in.
The compressor is switched off.
The compressed air supply is not
connected.
Refer to the Instructions for Use
for the respective gas detector or
sensor
Servicing is due.
A sensor is defective.
A cable is broken.
The gas concentration has risen
very quickly by more than 50 % or
has exceeded the limit value.
The gas concentration has fallen
below the limit value.
The sensor is drifting below the
zero-point.
Gas concentration exceeds full
scale value.
The gas concentration is
approaching the limit value.
The lamp test is being carried out. Wait for completion of the lamp test (approx. 100 seconds).
The activated charcoal tube is
saturated.
The front insulation is worn.
Remedy
Have an electrician inspect the circuit breakers -4F1 and
-4F2.
Remove the kink from the hose or, if necessary, have
authorised technical personnel replace the hose.
Have authorised technical personnel correct the limit values.
Replacement of the distribution system by authorised
technical personnel
Remove the kink from the hose or, if necessary, have
authorised technical personnel replace the hose.
Restore the hose connection or, if in doubt, have authorised
technical personnel restore the connection.
Have authorised technical personnel replace the hose.
Check the inlet pressure and increase it if necessary.
Refer to PID 5000 Instructions for Use
Refer to gas detector Instructions for Use
Log in a user.
Start the compressor.
Establish the compressed air supply.
Do not fill any breathing air. Remove the cause of the
contamination and purge the system. If need be, clean the
contaminated pressure vessels.
If the error persists, contact Dräger Service.
Contact Dräger Service.
Contact Dräger Service.
Contact Dräger Service.
Do not fill any breathing air. Remove the cause of the
contamination and purge the system. If need be, clean the
contaminated pressure vessels.
Do not fill any breathing air. Remove the cause of the
contamination and purge the system. If need be, clean the
contaminated pressure vessels.
Calibrate the zero-point and replace the sensor if necessary.
Do not fill any breathing air. Remove the cause of the
contamination and purge the system. If need be, clean the
contaminated pressure vessels.
Observe the display and take action if necessary.
Contact Dräger Service.
Contact Dräger Service.
Troubleshooting
en
29