Manufacturer
Lubricant
Mobil DTE Oil BB
Shell Tellus Öl C 220
Wintershall Ersolon 220
Wintershall Wiolan CN 220
RANDO HD 220
TOTAL Cortis 220
Check the oil level and if necessary refill from the oil dipstick
pos. , Fig. 3.
The correct checking of the oil level is made with the pump
not running, at room temperature. The oil change must be
made with the pump at working temperature, removing: the
oil dipstick, pos. , and then the plug pos. , Fig. 3.
The oil check and change must be carried out as indicated in
the table in chapter 11.
The quantity required is ~ 3.8 liters.
Viscosity / Room Temperature diagram
mm
/s = cSt
2
The used oil must be poured unto a suitable container and consigned to an authorized recycling center.
Do not release used oil into the environment under any circumstances.
Set up the plant so that the oil temperature never
exceeds 110°C (230°F) during pump operation
under any circumstances.
Use a temperature probe to be inserted into the
oil drain plug pos.(2) fig.3. See "ATEX EXPLOSION
PROTECTION" manual.
ATTENTION: Use only oil with a flash point higher
than 200°C.
In any case the oil must be changed at least once
a year, as it is degraded by oxidation.
For a room temperature other than between 0°C - 30°C, follow
the instructions in the following diagram, considering that oil
must have a minimum viscosity of 180 cSt.
Ambient temp. (°C)
29
Fig. 3