LED
E
RAPIDLY
RROR
FLASHING
Potentiometer not at 0
Forward and reverse controls
enabled at the same time
LED
E
SLOWLY
RROR
FLASHING
1
Motor not still at the start
2
Relay contact fault
3
Too low supply voltage
4
Too high supply voltage
5
Relay driver fault
6
Broken Potentiometer
7
Temperature fault
8
Fault while in motion
9
Fault on parameters setting
10
Wrong Checksum
14
Too high rotor current
on the left motor
16
Too high rotor current
on the right motor
17
Idleness fault
19
Program memory CRC fault
20
Parameters memory CRC fault
21
Device not registered
22
External fault
23
Serial communication fault
TABELLA 1
P
OSSIBLE CAUSES AND SOLUTIONS
At least one of the two potentiometers is being adjusted. Set it to 0.
Put running switches in neutral position and the potentiometer at the minimum.
P
OSSIBLE CAUSES AND SOLUTIONS
When the key switch is switched on the motor is turning. If the error persists power parts could be
damaged. Contact after sales service.
Check the main contactor according to the procedure described in the error section 5 "Relay driver
fault".
Battery voltage is below the min. value.
Battery voltage has exceeded the max voltage allowed for the controller.
• The contactor must be in good conditions and the mobile part must be able to move.
• The coil resistor value (when cold) must be higher than 9 Ohm.
• Coil wires should not be damaged or stripped.
• Pellets should not be worn out nor show important signs of burning.
• The voltage measured on coil ends in all contactors controlled by the control system is about
24V for the first seconds and then 11V.
• On coil positive (White) battery voltage must always be present when the switch is in on position.
Check that the wires connected to the potentiometer are not interrupted.
Check controller and base coupling. If the error is repeated contact after sales service
The controller has been switched off when the vehicle was moving. Always turn the controller off
when the vehicle is stopped.
The battery voltage is higher than 60V, that is the max voltage allowed for the controller
Programming procedure has been interrupted. Repeat it.
Contact after sales service
Contact after sales service
The time set for stand-by period has been exceeded.
Contact after sales service
Contact after sales service
Contact after sales service
Controller shutoff has been required by the input or serially by another device.
Communication is interrupted. Check serial wiring.