Descargar Imprimir esta página

Angelo Po 1N1PI1E Manual De Uso página 107

Marmita indirecta “eléctrica”

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Important
The connection must be made by authorised,
skilled personnel, in accordance with the rel-
evant legal requirements, using appropriate
and specifi ed materials.
The appliance is supplied with operating
voltage 400V/3 (230V/3 available on re-
quest).
Important
Specify the correct voltage for your device; it
cannot be modifi ed after purchase.
Cautela - Avvertenza
Before doing any work, cut off the mains
electricity supply.
Connect the appliance to the mains electricity
supply as follows:
B
D
3320140_inst_GB_rev.1
ELECTRICAL CONNECTION
A
C
If not already present, install a circuit-breaker
1)
(A) with overload cutout and diff erential safety
breaker close to the appliance.
Remove the knob unit (B).
2)
Undo the screws (C) and remove the control
3)
panel (D).
Connect the circuit-breaker (A) to the terminal
4)
board (E) of the appliance as shown in the
diagram and in the electrical system diagram
at the back of the manual.
Use a fl exible cable with at least type H07RN-
Fcharacteristics, rated for an operating tem-
perature of at least 80°C.
Important
When connecting, take care to connect the
neutral and earth lines.
Replace the control panel (D) and the knobs
5)
(B) on completion of the operation.
C
E
- 11 -
GB