If the safety thermostat is tripped because the
water level in the jacket is too low, the applian-
ce has to be restored to working conditions as
follows.
Check and if necessary top up the water level
1)
in the jacket (see page 10).
Press the button (A) of the safety thermostat
2)
to restore the Electricity supply.
Caution - Warning
If the safety thermostat is tripped too often,
and the water level in the jacket is correct,
call the after-sales service.
If the appliance is to be out of use for a lengthy
period, proceed as follows.
Cut off the mains electricity supply using the
1)
appliance's master switch.
Clean the appliance and the surrounding
2)
areas thoroughly.
To ensure correct use of the appliance, the
following rules should be adopted.
– Use only the accessories recommended by
the manufacturer.
– When fi lling the jacket, do not use water with
hardness in excess of 10° f.
– Do not obstruct the safety valves during use.
3320140_ut_GB_rev.1
RESETTING THE APPLIANCE
LENGTHY DOWNTIMES OF APPLIANCE
INSTRUCTIONS AND WARNINGS FOR USE
A
Spread a fi lm of edible oil over the stainless
3)
steel surfaces.
Carry out all the servicing procedures.
4)
Cover the appliance and leave a few gaps to
5)
allow air to circulate.
– Check that the water level never exceeds the
maximum level.
Important
During use, check that the pressure gauge
reading does not exceed 0,5 bar.
- 11 -