Descargar Imprimir esta página

Interpump Group 71VHT Serie Manual De Uso Y Mantenimiento página 21

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 70
4. The work area jet range must be absolutely prohibited to
and free from objects that, inadvertently under a pressure
jet, can be damaged and/or create dangerous situations.
5. The water jet must always and only be pointed in the
direction of the work area, including during preliminary
tests or checks.
6. The operator must always pay attention to the trajectory
of debris removed by the water jet. Where necessary,
suitable guards must be provided by the Operator to
protect anything that could become accidentally exposed.
7. The operator should not be distracted for any reason
during work. Workers needing to access the operating area
must wait for the Operator to stop work on his/her own
initiative, after which they should immediately make their
presence known.
8. It is important for safety that all team members are always
fully aware of each other's intentions in order to avoid
dangerous misunderstandings.
9. The high pressure system must not be started up and run
under pressure without all team members in position and
without the Operator having already directed his/her lance
toward the work area.
3.5
Safety during system maintenance
1. High pressure system maintenance must be carried out
in the time intervals set by the manufacturer who is
responsible for the whole group according to law.
2. Maintenance should always be performed by trained and
authorized personnel.
3. Assembly and disassembly of the pump and the various
components must only be carried out by authorized
personnel, using appropriate equipment in order
to prevent damage to components, in particular to
connections.
4. Always only use original spare parts to ensure total
reliability and safety.
5
TECHNICAL CHARACTERISTICS
Model
Rpm
1000
VHT 71150
900
800
6
DIMENSIONS AND WEIGHT
For Standard Version pump dimensions and weight, refer to Fig. 2.
Dry weight 68 kg.
4
Each pump has its own Serial No. XX.XXX.XXX see pos.  and
an identification plate see pos.  in Fig. 1 which shows:
-
Pump model and version
-
Max revs
-
Absorbed power HP - kW
-
Pressure bar - P.S.I.
-
Flow rate l/min - Rpm
Flow rate
l/min
Gpm
188
49.7
170
44.9
150
39.6
21
PUMP IDENTIFICATION
Model, version and serial number must always be
indicated when ordering spare parts
Pressure
bar
psi
100
1450
35.9
110
1595
110
1595
Fig. 1
Power
kW
HP
48.8
35.7
48.6
31.5
42.8
Fig. 2