Installation and Connection
NOTE!
It's necessary to program the digital input DI2 for the three-wire command function.
Refer to item 4.10.
NOTE!
The RL1 shall be set to the "No fault" function. Refer to item 4.12.
3.3.3 Recommended Set-up with Command via Two-wire Digital Inputs and Direction
3
of Rotation
P220 = 1
P230 = 1
P263 = 1 (DI1 = Start/Stop two
wires)
P265 = 4 (DI3 = Rotation Direction)
P277 = 4 (RL1 = FWD/REV - K1)
P278 = 4 (RL2 = FWD/REV - K2)
Refer to notes in item 3.3
Figure 3.12: Recommended Set-up with Command via Two-wire Digital Inputs and Direction of Rotation
NOTE!
To program the parameters shown above, is necessary the use of keypad or serial
communication. See the Programming Manual for more information.
22 | SSW-08
R
S
T
P E
K1
K2
R S T
A1
U V W
M
3~
T1
A2
DI1
DI2
DI3
K1
K2
13
14
23
24
RL1
RL2