- Connect signal cable for external devices managment to con-
nector (6).
- Connect the signal cable (9) of RC350 to the appropriate con-
nector (10) of the power source.
- Connect the earth clamp (11) to the negative socket (-) (12) of
the power source.
- Connect the MIG/MAG torch (13) to the central adapter (14),
ensuring that the fastening ring is fully tightened.
- Connect the water pipe (15) (red colored
to the inlet quick connector (16) of the cooling unit.
- Connect the water pipe (17) (blue colored
to the outlet quick connector (18) of the cooling unit.
36
SIGNAL
A
+24V IN
B
GND
C
+24V OUT
D
GND
E
DO 5 DIGITAL OUTPUT
F
DO 6 DIGITAL OUTPUT
G
DO 7 DIGITAL OUTPUT
H
DO 8 DIGITAL OUTPUT
J
DO 2 DIGITAL OUTPUT
K
COM
L
NOT USED
M
ELV 1
N
ELV 2
P
ELV 3
R
ELV 4
S
ELV 5
T
U
PE
V
NOT USED
) of the torch
) of the torch
3 SYSTEM PRESENTATION
3.1 Front control panel
1
Power supply
Indicates that the equipment is connected to the mains
and is on.
2
General alarm
Indicates the possible intervention of protection devices
such as the temperature protection (consult the "Alarm
codes" section).
3
Power on
Indicates the presence of voltage on the equipment
outlet connections.
4
Signal cable (CAN-BUS) input (RC)
5
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.