330
Voltage
Lets you set welding voltage.
398
Welding speed
Sinergic value.
399
Welding speed
Lets you set welding speed.
Minimum 20cm/min, Maximum 200cm/min, Default
35cm/min (reference speed for manual welding).
Syn: Sinergic value.
500
Allows the selection of the required graphic interface:
XE (Easy Mode)
XA (Advanced Mode)
XP (Professional Mode)
Allows access to the higher set-up levels:
USER: user
SERV: service
SELCO: Selco
551
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
552
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
601
Regulation step
Allows the regulation of a parameter with a step that can
be personalised by the operator.
Minimum 1, Maximum Imax, Default 1
602
External parameter CH1, CH2, CH3, CH4
Allows the management of external parameter 1,2,3,4
(minimum value, maximum value, default value, param-
eter selected).
(Consult the "External controls management" section).
606
U/D torch
Allows the management of the external parameter
(U/D).
O=off, I=current, 2=program retrieval
652
Double wire feeder synchronizing
Allows to synchronize the wire speed of two system in
series.
Parameter setting: meters per minute (m/min).
Minimum -0.50 m/min, Maximum +0.50 m/min,
Default syn
653
Wire speed
It allow wire speed regulation (during wire loading
phase).
Minimum 0.5 m/min, Maximum 22 m/min, Default 3
m/min
705
Circuit resistance calibration
Lets you calibrate the system.
Press the encoder knob to access parameter 705.
Place the tip of the wire guide in electrical contact with
the work piece.
Press and hold the torch trigger for at least 1 s.
751
Current reading
Allow the real value of the welding current to be dis-
played.
752
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
755
Gas flow reading
Allows the real gas flow value to be displayed.
40
757
Wire speed reading
Allow the value of the motor encoder 1 to be displayed.
758
Robot movement speed
Allows the arm movement speed of a robot or an auto-
mation device to be displayed.
760
(Motor) Current reading
Allow the real value of the (motor) current to be dis-
played.
761
Wire speed reading
Allow the value of the motor encoder 2 to be displayed.
762
(Motor) Current reading
Allow the real value of the (motor) current to be dis-
played.
763
Wire speed reading
Allow the real value of the wire speed to be displayed.
764
Coolant flow reading
Allow the value of the coolant flow reading.
765
Coolant temperature reading
Allow the real value of coolant temperature reading to
be displayed.
801
Guard limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the "Guard limits" section).

Publicidad