Descargar Imprimir esta página

Selco Genesis 4000 PSR Instrucciones De Uso página 48

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 107
E75
Motor 2 current level exceeded (Warning)
E76
Liquid coolant flow level exceeded
(Warning)
E77
Coolant temperature level exceeded
(Warning)
3.13 Rear panel
1
Power supply cable
Connects the system to the mains.
2
Signal cable (CAN-BUS) input (RC-RI)
3
Signal cable (CAN-BUS) input (WF)
4
Signal cable (Robot) input
3.14 Sockets panel
P1
Negative power socket
Allows the connection of the earth cable in MIG/MAG
and Pulsed MIG/MAG.
P2
Positive power socket
48
4 ACCESSORIES
4.1 General (RC)
Operation of the remote control is activated when connected
to the Selco power sources. This connection can be made also
with the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 350 remote control
The RC 350 is a remote control unit designed to manage the
display and the adjustment of all available parameters of the
power source to which it is connected.
"Consult the instruction manual".
4.3 Additional supply kit (74.04.060)
"Consult the "Installation kit/accessories" section".
4.4 Nozzle sensing - Cleaning station kit
(74.04.059)
"Consult the "Installation kit/accessories" section".
4.5 RC bracket kit (74.04.045)
"Consult the "Installation kit/accessories" section".
5 MAINTENANCE
Routine maintenance must be carried out on the
system according to the manufacturer's instruc-
tions.
Any maintenance operation must be performed by qualified
personnel only.
When the equipment is working, all the access and operating
doors and covers must be closed and locked.
Unauthorized changes to the system are strictly forbidden.
Prevent conductive dust from accumulating near the louvers
and over them.
Disconnect the power supply before every opera-
tion!
Carry out the following periodic checks on the
power source:
- Clean the power source inside by means of
low-pressure compressed air and soft bristle
brushes.
- Check the electric connections and all the connec-
tion cables.

Publicidad