Welding parameters
2a Welding parameters
Select the required parameter by pressing the encoder
button.
Adjust the value of the selected parameter by rotating
the encoder.
2b Parameter icon
2c Parameter value
2d Unit of measurement of the parameter
3
Functions
Allow the setting of the most important process func-
tions and welding methods.
3a
Allows the selection of the welding process
Standard MIG/MAG
Pulsed MIG/MAG
3b
Allows the selection of the welding method
Robotics
3c
Double pulsed inactive
Double pulsed active
3d
Display type
38
4
Measurements
During the welding operation, the real current and volt-
age measurements are shown on the LCD display.
4a Welding current
4b Welding voltage
3.5 Set up
Permits set up and adjustment of a series of additional param-
eters for improved and more accurate control of the welding
system.
The parameters present at set up are organised in relation to the
welding process selected and have a numerical code.
Entry to set up: by pressing the encoder key for 5 sec. (the
central zero on the 7-segment display confirms entry).
Selection and adjustment of the required parameter: by
turning the encoder until displaying the numerical code relating
to that parameter. If the encoder key is pressed at this point,
the value set for the parameter selected can be displayed and
adjusted.
Exit from set up: to quit the "adjustment" section, press the
encoder again.
To exit the set up, go to parameter "O" (save and quit) and press
the encoder.
List of set up parameters (MIG/MAG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2
Synergy
Allows selection of the manual MIG (
gic MIG (
) process by setting the type of mate-
rial to be welded.
(Consult the "Synergic curves screen" section).
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 22 m/min (25 m/min),
Default 1.0m/min
4
Current
Allows the regulation of the welding current.
Minimum 6A, Maximum Imax
) or syner-