BMP 01- EL1PP _ 1A- _ _ _ _ -00 -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
3

Construction and function

BMP 01-...-S4
50
BMP 01-...-S75
40
BMP 01-...-cable
Marking of the measuring range
1)
Not included in scope of delivery
2)
3)
Attachment position (see Fig. 4-13
on page 12)
Fig. 3-1:
BMP Magnetic Field Positioning System 01-..., structure and function
3.1

Construction

Electrical connection: The electrical connection is made
via a cable with or without a connector (see type code on
page 31).
Housing: Aluminum housing with plastic closures.
Housing length: Measuring range + 10 mm.
Attachment: Holes are provided in the BMP for
attachment using M2 mounting screws or slot nuts (see
accessories on page 30).
Target: Defines the position to be measured.
Measuring range: For adapting the BMP to the
application optimally, the following measuring ranges are
available: 32/64/96/128/160/192/224/256 mm. The values
listed in the Technical data (see Sec. 8.1 on page 29)
are maintained for repeat accuracy and non-linearity.
Detection range: Range in which the BMP detects the
position of the target. It extends beyond the measuring
range by 4 mm on both sides.
The detection range which goes beyond the
measuring range is only output via the IO-Link
interface.
www.balluff.com
1)
Groove
Target 2)
Measuring range
2
Detection range
Housing length
3
3)
2
LED
Button
3.2
The BMP is an intelligent magnetic field positioning system.
It is used primarily for the non-contact detection of the
piston stroke of pneumatic cylinders, grippers and slides
with axially magnetized permanent magnets. The BMP
ensures continuous, absolute position measurement at an
application-relevant level of measuring accuracy.
The analog output of the BMP is easy to evaluate and can
be switched between voltage and current. It also offers a
switching output that is easy to adjust.
Using the button and the three LEDs, the BMP can be
configured without addition auxiliary tools.
Over the IO-Link interface, the BMP offers additional
configuration options and state monitoring functions.
The functions of the BMP allow it to support simple format
change in different applications.