8.5 - Adjusting the limit switches on the front profile
To adjust the mechanical limit switches, loosen the screw shown in
the figure and move the limit switch to the correct position. Tighten
the screw.
N.B. Do not overtighten the screw. During operation, the panel
will stop approximately 10 mm before the limit switch buffer
8.6 - Wiring the door to the line
Connect the network cables to the line input terminal as shown in
the image. The line must be adequately protected against short
circuits. Fasten the 230 Vac cable with a cable tie to the hole below
(A).
9 - INSTALLATION OF PROTECTION PANELS
9.1 - Mounting the side covers
The following figure shows the side covers in the two variants, right
R and left L, where right means the cover that is mounted on the
Cover
left side
The assembly of the cover, as shown in the following figure, takes place by screwing 2 self-tapping screws onto the extruded aluminium
of the front beam.
ATTENTION !
Pay attention to the overall dimensions of the automation for
versions with recessed beams on a wall compartment. In the
"recessed" versions it is in fact necessary to consider 5mm in
addition to the length of the beam to consider the thickness of the
side caps, and they will be fixed to the section of the front beam
profile before it is mounted on the profile of the rear telescopic
beam.
60
right end of the beam seen from the front and the same for the left.
Cover
right side
Cover panel fixing
bracket
L
A
N
Cover panel fixing
bracket