Descargar Imprimir esta página

Key Automation TELESCOPIC LEVANTE Serie Instrucciones Y Advertencias Para Su Instalación Y Uso página 75

Actuador para puertas automáticas de corredera

Publicidad

Idiomas disponibles

Idiomas disponibles

12.5 - Error code examples
Error
No communication between function selector and equipment. The incorrect or absence of connection of the function
E00
selector causes the appearance of the error E 00 on the display of the PRO selector and non-operation of the
E101
E201
Obstacle detected due to encoder stopped during closure. The equipment continues normal operation.
E102
E202
Obstacle detected with encoder stopped in opening. The equipment continues normal operation.
E03
Faulty encoder. The equipment stops and will only attempt to resume operation after being reset or turned off.
E04
E05
Low battery. The equipment normally continues operation as long as the battery voltage permits it.
Learned stroke greater than the maximum permitted. The equipment will only attempt to resume operation after
E06
E07
Motor polarity reversed or encoder channels reversed. The equipment stops and will only attempt to resume
E08
Weight detected higher than the max. permissible. The equipment will only attempt to resume operation after being
E09
E10
Overload protection of the power circuit has occurred. The equipment will attempt to resume operation after a new
E11
EEPROM memory read or write error The equipment will attempt to resume operation only after being reset or
E12
E13
E14
E15
E16
E17
E18
Excessive temperature of the power electronics. The equipment will only attempt to resume operation after being
E19
E20
Power electronics failure, The equipment will only attempt to resume operation after being reset or turned off.
PROGRAM MENÙ
P1
ESC
P5
ESC
MENU
Obstacle detected with closing current. The equipment continues normal operation.
Obstacle detected with opening current. The equipment continues normal operation.
Power supply absent. The equipment continues operation, as set with parameter F.
Flat battery. The equipment stops.
operation after being reset or turned off.
Motor current greater than the maximum permissible detected.
The equipment will attempt to resume operation after a new command.
Monitored device test 1 failed PHOTO command
Monitored device test 2 failed PHOTO command
Monitored device test 1 failed PHOTO RALL command
Monitored device test 2 failed PHOTO RALL command
Monitored device test 1 failed STOP command
Monitored device test 2 failed STOP command
OK
P1
P4
P2
OK
AS
P2
Description
equipment display
being reset or turned off.
reset or turned off.
command.
turned off.
reset or turned off.
EN
75

Publicidad

loading