EN
11.20 - Displays
By pressing the ESC key it is possible to view in sequence:
CTOT The total number of cycles performed by the automation,
expressed in hundreds.
CPAR The partial number of cycles performed by the automation,
POSE
CORS
RALA
RALC
UBAT
n
IMOT
n
UMOT
SOGO
UERR
n
TEMP
VACC
AUTS
After 60 seconds of inactivity the display returns to showing the
operating mode.
72
PROGRAM MENÙ
P5
ESC
MENU
Door position (in encoder counts)
Learned stroke (in encoder counts)
Learned opening approach space (expressed in encoder count)
Learned closing approach space (expressed in encoder count)
Battery voltage (expressed in volts)
Instantaneous current (in 1/100 amps) if the door is in motion. Max current of the last movement if the
door is stopped.
Motor voltage (in volts)
Obstacle current threshold (in 1/100 amps)
They are automatically displayed in sec. intervals. The codes of the last 16 errors that have occurred,
numbers from 1 the most recent to 16 the least recent.
The temperature of the power electronics is displayed in vn degrees centigrade.
The supply voltage of the accessories is displayed in volts.
This information is displayed every time parameters of the board are changed and the next two door
operations will re-check all the parameters.
expressed in hundreds: this counter can be reset by holding the
OK button for two seconds until the sounding of an acoustic signal.
If the OK button is kept pressed while the display is off (until a
beep is heard), the ESC key can be used to view other particular
information in real time:
P1
P4
P2
OK
AS
by pressing the + key it is possible to temporarily display the weight
class currently configured.