Descargar Imprimir esta página

Corghi EM9780 plus Manual De Uso página 52

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

A
B
Wheel guard and related
support mounting procedure
- Install the bush (A, fig. 7) on the pivot (B, fig.
7). While doing this, ensure that the groove on
the pivot is aligned with the pin in the bush;
B A
- Block the bush on the pin using the M12 screw
supplied with the machine.
- Insert the metal tube (D, fig.8) into the two
plastic guard front holes (C, fig.8);
- Fasten the guard to the rear of the pipe, snap
fitting into the relative seat (E, fig. 8);
- Lock the guard by tightening the screw F (fig.8).
52
EM9780 plus - EM9780 C plus AutomaticLine - Operator's manual
C
6
D
7
Mounting the ultrasonic
sensor and its automatic width
detection support
- Introduce the ultrasonic sensor cable inside the
slots on the metal tube (see fig. 8a);
- Fix the ultrasonic sensor support to the pro-
tective tube using the three screws provided
(Fig. 8b);
8
8a

Publicidad

loading

Este manual también es adecuado para:

Em9780 c plus automaticline