- with the wheel NOT in a centered position
and the operator presses and keeps pressed
the LIVE button, if the ALU1 or ALU2 balanc-
ing programme is selected, the machine will
request confirmation for both positions. Posi-
tion 1 is indicated in figure 15 (for a spring
weight, i.e. ALU2) and figure 15a (for an
adhesive weight, i.e. ALU1) whereas position
2 is indicated in figure 15c.
If one of the two proposed application positions
is correct it is necessary:
- press and release the LIVE button on the weight
door cover (see figure 15b);
Position 2
- after confirmation, the machine will automati-
cally recalculate the unbalances in correspond-
ence of the new set positions.
- It is possible to exit the LIVE environment by
pressing the
68
EM9780 plus - EM9780 C plus AutomaticLine - Operator's manual
15b
15c
button on the monitor.
In this case the measured dimensions are NOT
confirmed and the machine will again request
confirmation, as shown in the figure.
Note: the edge or the plans acquired automati-
cally by the machine can be changed either by
using the
button or using the
button shown in figure 15.
CAUTION
The status of the internal sensor is indicated
in the LIVE programme (Fig.15). If it is GREEN
, this means that the laser is reading
correctly, whereas if it is RED
means that the laser does NOT read. To remedy
this situation, move the wheel slightly until the
sensor status changes.
If the sensor configuration does NOT change by
moving the wheel (or using a different wheel)
enter the dimensions manually and contact
technical support.
Note: the balancing planes where the adhesive
weights are to be applied may be selected by
the user according to the specific shape of the
rim. It should be remembered, however, that in
order to reduce the quantity of the weight that is
to be applied it is preferable to select balancing
planes that are as far apart as possible: if the
distance between the two planes is less than 37
mm (1.5"), the A 64 message is displayed.
Dynamic balancing (Dynamic)
This balancing mode is the most commonly used
one. If a different balancing programme is run-
ning, the programme must be set by selecting
the correct icons.
Now proceed as follows:
-
Press the Dimensions button
enable automatic dimension measurement.
The button remains pressed and the inner
light turns red
this
to
.