Calibration of the ultrasonic width sensor (if installed)
Used to calibrate the ultrasonic sensor located on the wheel guard pipe (width). It must
be performed when the machine requests it by displaying the E4 message, or when the
measured and the actual rim widths differ.
- select the ultrasonic width sensor calibration icon
programmes;
- fix the calibration template in correspondence of the threaded hole located in the shaft
assembly bell using the M8 screw (A, Fig.28) supplied with the ultrasonic sensor;
- use the locking device with a wheel spacer (machine version with automatic locking
system) or a cone and the wheel fixing nut to bring the template in contact with the
shaft assembly bell (fig.28);
- press ENTER to confirm the securing of the template;
- slowly turn the template towards the operator to automatically enable the clamping
brake (fig.29);
- slowly lower the wheel guard (fig. 30), the machine will automatically calibrate the sen-
sor.
128
located in the configuration
28
29
Operator's Manual S 65 E - S 65 E C