sibility and at the charge of the customer.
- The electric hook-up must be performed according to:
• absorbed power specifications indicated on the machine dataplate.
• the distance between the machine and the electric hook-up point, so that voltage drops
under full load do not exceed 4% (10% when starting up) of the rated voltage specified
on the data plate.
- The user must:
• fit a plug that respects the current regulations onto the power supply cable;
• connect the machine to its own electrical connection fitted with a suitable 30-mA current
sensitive circuit breaker;
• fit power supply protection fuses sized in compliance with specifications in the main
wiring diagram of this manual;
• provide the workshop electric installation with an efficient grounding circuit.
- prevent unauthorised use of the machine, always disconnect the power supply plug when
the machine is not used (switched off) for extended periods of time.
- If the machine is connected directly to the power supply by means of the main electrical
board and without the use of a plug, install a key-operated switch or suitable lock-out
device to restrict machine use exclusively to qualified personnel.
CAUTION
For the machine correct functioning it is vital to have a good ground connection. NEVER
connect the machine ground wire to a gas pipe, water pipe, telephone cable or any other
unsuitable object.

COMPRESSED AIR HOOK-UP

CAUTION
All compressed air hook-ups must be carried out by qualified personnel only.
- The hook-up to the workshop's pneumatic system must ensure a minimum pressure of
7 bar (100 psi). Lower pressure levels may prevent the machine's AUTOMATIC WHEEL
LOCKING SYSTEM C from working properly.
- A universal union is used for connection to the compressed air system. No special or
additional adaptor is needed for connection. A pressure-resistant hose with 6mm inner
diameter and 14mm outer diameter must be fastened to the notched union using the
clamp provided with the machine.
82
Operator's Manual S 65 E - S 65 E C