Maintenance - SICE S 65 E Manual De Instrucciones

Equilibradora de banco
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

The machine has not been calibrated correctly.
Carry out the sensitivity calibration procedure.
The entered geometric data are not correct.
Check that the data corresponds to the dimensions of the wheel and correct, if
necessary.
Perform the width sensor calibration procedure.
LED light and/or laser indicator are NOT working
Check if the device(s) is (are) configured correctly as shown in the paragraphs "lighting
LED activation/deactivation" and "LASER activation/deactivation". If the problem persists
after checking the correct device configuration, call the technical support centre.
CAUTION
The "Spare parts" handbook does not authorise the user to carry out work on the ma-
chine with the exception of those operations explicitly described in the User Manual.
It only enables the user to provide the technical assistance service with precise infor-
mation, to minimise delays.
CAUTION
The company is not to be held responsible for any claims deriving from the use of
non-original spare parts or accessories.
CAUTION
Unplug the machine from the socket and make sure that all moving parts have been
locked before making any adjustments or maintenance work.
Do not remove or modify any part of the machine (except for service interventions).
WARNING
Keep the working area clean.
Never use compressed air and/or jets of water to remove dirt or residues from the
machine.
Take all possible measures to prevent dust from building up or raising during clean-
ing operations.
Keep the wheel balancer shaft, the securing ring nut, the centring cones and flange clean.
These components can be cleaned using a brush previously dripped in environmentally
friendly solvents.
Handle cones and flanges carefully so as to avoid accidental dropping and subsequent
damage that would affect centring accuracy.
After use, store cones and flanges in a place where they are suitably protected from dust
and dirt.
If necessary, use ethyl alcohol to clean the display panel.
Perform the calibration procedure at least once every six months.
134

MAINTENANCE

Operator's Manual S 65 E - S 65 E C