unscrewing the four fixing screws (Fig.6c).
- check and if necessary act on the ultrasonic
sensor support until obtaining the required
distance between the calibration template
and the support itself (Fig.6d), proceeding
as follows:
1. Fix the calibration jig of the ultrasonic sen-
sor in the kit to the shaft of the oscillating
unit using the centering accessories;
2. Lower the wheel guard;
CAUTION
Lowering the wheel protection enables the
launch of the oscillating unit with the template locked !!!
3. Align the calibration gauge of the ultrasonic sensor with the ultrasonic sensor holder
and check its distance, ie:
a. 270mm (tolerance +/- 5mm)
IMPORTANT: after installing the ultrasonic sensor, calibrate the sensor as described
in the paragraph "Calibrating ultrasonic width measuring sensor".
After assembling the machine, posi-
tion it in the selected place and make
sure that the spaces surrounding it
are at least equal to the ones indi-
cated in fig.7.
80
Operator's Manual S 65 E - S 65 E C
6d
7