ENGLISH
supplied and taking into account the current regulations. Cecotec declines all liability in
the event of incorrect installation, which may cause injury to people and animals, as well
as damage to property.
-
Important: the appliance must be disconnected from the mains before any adjustment or
maintenance work is carried out on it.
-
The air duct is used for ventilation.
-
In order for the built-in appliance to function properly, the cabinet containing it must
be suitable. Figure 2 shows the dimensions (in mm) required for installation under the
worktop or in a wall unit.
-
To ensure adequate ventilation, the rear panel of the cabinet must be removed. It is
preferable to install the oven so that it rests on two wooden slats. If the oven rests on a
flat surface, there must be an opening of at least 45×560 mm.
-
Adjacent cabinet panels shall be made of heat-resistant material. In particular, enclosures
with a veneered exterior must be assembled with glues that can withstand temperatures
up to 100 ºC.
-
In compliance with current safety regulations, it must not be possible to come into contact
with the electrical parts of the oven once it has been installed.
-
All parts that ensure the safe operation of the appliance must only be removed with the
aid of a tool (NOT INCLUDED).
-
To fix the oven to the cabinet, open the oven door and fix it by inserting the 4 screws into
the 4 holes on the perimeter of the frame.
Electrical connections
Ovens equipped with a three-pole power cable are designed to operate on alternating current.
The cable for the grounding of the device is yellow green.
Mounting the power cable
Opening the terminal box (Fig. 3):
1.
Using a screwdriver, prise the bolt on the side tabs of the terminal box cover.
2.
Unscrew the screw and open the cover.
3.
To install the cable, proceed as follows:
4.
Remove the cable clamp screw and the three contact screws.
5.
Fix the wires under the screw heads using the following colour scheme:
-
Blue - Neutral (N)
-
Brown phase connector (L)
-
Yellow-Green (Ground)
6.
Secure the power cable with the cable clamp and close the terminal box cover.
Connecting the power cable to the mains
-
Install a standard plug (not included) corresponding to the load indicated on the rating
plate. When connecting the cable directly to the mains, install an omnipolar circuit
breaker with a minimum contact opening of 3 mm between the device and the mains.