Descargar Imprimir esta página

Fronius Robacta Drive CMT G Manual De Instrucciones página 62

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 126
Technical data
CMT G
Explanation of symbols
X
ED*
I
Voltage measurement (V-Peak):
for mechanically driven welding torches: 141 V
This product conforms to the requirements of IEC 60974-7.
X / I
(10 min /
max
40°C)
M21 (EN 439)
X / I
(10 min /
max
40°C)
C1 (EN 439)
Ø
62
Gas cooling
Length of the hosepack
Duty cycle in %
Duty cycle
max. welding current in A
max
Electrode diameter
Ø
MTG 2500
[%] / [A]
-
[%] / [A]
60 / 200
[%] / [A]
100 / 150
[%] / [A]
-
[%] / [A]
60 / 250
[%] / [A]
100 / 190
[mm]
0,8 - 1,2
[in.]
.031 - .047
MTG 3200
MTG 4000
-
-
60 / 260
60 / 320
100 / 200
100 / 250
-
-
60 / 320
60 / 400
100 / 250
100 / 310
0,8 - 1,2
0,8 - 1,6
.031 - .047
.031 - .063