Air motor attachment
1 Refer to fig. 2 Hand tighten tie rods to
the air motor (use short threaded end of
the tie rods)
2 Mount air motor on top of the pump tube
outlet body and tightly connect coupling
adapter (10) to air motor piston rod
3 Hand tighten tie rods to the pump tube
with four nuts supplied with air motor
4 Slowly cycle the pump several times,
using just enough air pressure to operate
the pump without stalling
NOTE
Pumps are factory tested with oil and
some of it is left in to protect pump parts
during storage and transportation
To prevent contamination of material to
be pumped, flush pump before using
5 Stop the pump on an "up" stroke and
tighten the four nuts to securely fasten
the air motor to the pump tube
Maintenance and
repair
Relieve pressure from the pump and supply
lines and remove or lockout air line to air
motor before servicing or repairing pump
tube to reduce the risk of an injury from
injection, spraying fluid or moving parts
For common issues and suggested solu-
tions, refer to Troubleshooting, page 13.
Disassembly
Outlet housing
1 Refer to fig. 2 Unscrew coupling
adapter (10) from plunger rod (5)
2 Unscrew bushing nut (9)
from outlet body (11)
3 Remove v-packing set (8)
from bushing nut (9)
4 Remove six wave washers (12),
two flat washers (7) and o-ring (13)
from outlet body (11)
5 Remove adapter (14) from outlet body (11)
10
9
8
12
7
13
14
11
5
6