BTL AK _ A00- _ _ _ _ -C11WH120-000C51-001
Magnetostrictive Linear Position Sensor – Rod Style
6
Startup and operation
6.1
Startup
DANGER
Uncontrolled system movement
When starting up, if the sensor is part of a closed loop
system whose parameters have not yet been set, the
system may perform uncontrolled movements. This
could result in personal injury and equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the BTL if necessary. Check the values
over the entire measuring range.
Check for the correct values, especially after
replacing the BTL or after repair by the
manufacturer.
6.2
Operating notes
Regularly check function of the BTL and all associated
components.
Take the BTL out of operation whenever there is a
malfunction.
Secure the system against unauthorized use.
Check fasteners and retighten if needed.
www.balluff.com
6.3
Settings
Further information can be found in the
configuration guide online at www.balluff.com
on the product page.
6.3.1
Default
The BTL is delivered with the following settings:
Node ID
Resolution:
Position
Velocity
Maximum working/useful range:
Switching points/cams
Data transfer
Terminating resistor
Baud rate
Changes to the BTL default settings are done in the SDO
protocol in accordance with SD 301.
6.3.2
Setting the node ID
The node ID is set via the POWER/Node ID connector (see
Fig. 5-12 on page 15).
6.3.3
Setting the bus termination
To ensure a reliable bus level, the bus must be terminated
at both ends with a terminating resistor (120 Ohm). This
must be realized outside the sensor.
6.3.4
PDO, data
2 PDOs have been provided in the communication profile
in order to transfer data.
A PDO consists of the following:
Position data, 4 bytes, integer
Velocity data, 2 bytes, integer
6.4
Maintenance
The product is maintenance-free.
4
5 µm
0.1 mm/s
None
7 ms
120 Ohm
as per order (see
Type code on
page 22)
english
17