c. In the case of brick or concrete walls or similar, make 7 x 5 mm diameter holes.
d. Insert the plugs (C) inside the holes (use suitable plugs on the basis of the type of wall).
e. Fix the plate (A) to the wall tightening all screws (B).
f.
Position the appliance (1) on the bracket (A) making sure to block the appliance through the hooks
(1a).
3.2.c - Drilling for condensate drain pipe
Using the template (I), establish the point where to drill to make the condensation drain pipe (E) and the
water pipes pass.
Make a 95 mm hole in the wall, which is angled downwards (figure 5).
Always use a wall hole conduit when piercing metal lath,ply wood or metal plate.
• Do not install the drain pipe as illustrated in figure 6.
• Do not form downward curves. Do not immerse the end of the pipe in water (figure 7).
When connection extension drain hose, in-
sulate the connecting part of extension drain
hose with a shield pipe.
3.2.d - Water connection pipes
Bend the connective pipe to be laid at 43mm height or less from the wall. (fig. 8).
Fix the end of the connective pipe. (Refer to Tightening Connection in WATER PIPING INSTALLATION).
After connecting, all connective pipe should be covered by heat-resistant materials.
• CONNECT THE APPLIANCE TAKING CARE TO BEND AND POSITION THE PIPE CORRECTLY.
• MAKE SURE THAT THE PIPES DO NOT CAUSE ESCAPE FROM THE REAR OF THE
APPLIANCE.
• BE CAREFUL NOT TO LET THE DRAIN HOSE SLACK.
• INSULATE BOTH OF THE AUXILIARY PIPING.
• BANDING THE DRAIN HOSE UNDER THE AUXILIARY PIPE.
• MAKE SURE THAT THE PIPES DO NOT CAUSE ESCAPE FROM THE REAR OF THE
APPLIANCE.
3.2.e - Fixing and protection of pipes
Wind the connective cable, drain hose and
wiring with tape securely, evenly as shown
Fig.D.
The condensate water that forms on the back
of the appliance deposits in a collection tray
and is conveyed outside the room.
Do not put anything else in the box.
EN - 10
C
Protection
Drain hose
D
Collection tank
Tubing compartment
Connecting pipes
Tube winding tape
Wall
Extension cord
Connecting
cable
Wall