MALFUNCTIONING
Cooling not very effective
Heating not very effective
Impossible to modify the fan speed
The TEMP indicator does not
switch on
The remote control signal is not
transmitted, even if the ON/OFF
key is pressed
The indication on the display dis-
appears after a certain period of
time
The TIMER ON indicator switches
off after a certain period of time
The appliance does not emit any
sound, not even when pressing
the ON/OFF key (P5)
Do not try to repair the appliance by yourself.
If the problem has not been solved, please contact your local retailer or the closest assistance service.
Supply detailed information about the malfunction and the equipment version.
EN - 26
CAUSE
Accumulation of dirt in the appli-
ance heat exchanger coil
Air filter dirty
Obstruction of the appliance inlet
Doors and windows open
Exposure to direct sunlight
Too many heat sources
Outdoor temperature too high
Outdoor temperature lower than
7°C
Doors and windows partially open Close doors and windows
Control that the MODE indicated
on the display is AUTO (automatic)
Protection against hot air in cool-
ing mode
Protection against cold air in heat-
ing mode
Control that the MODE indicated
on the display is FAN (ventilation)
Verify that the batteries of the re-
mote control are not discharged
The electric current is cut off
Check that the appliance stops
when the display shows the TIM-
ER OFF indication (switch-off tim-
er)
Check that the appliance starts
when the display shows the TIM-
ER ON indication (switch-on timer)
Check that the remote control sig-
nal transmitter is aimed correctly
towards the appliance infra-red re-
ceiver when the ON/OFF key (P5)
is pressed
WHAT MUST BE DONE?
Clean the heat exchange coil
Clean the filter
Eliminate the impurities to free the
air flow
Close doors and windows
Protect from solar rays via curtains
Reduce the heat sources
The conditioner cooling capacity
lowers (normal)
Use a heating device
If automatic mode is selected, the
conditioner automatically adjusts
the fan speed
Lower the inlet temperature in
cooling mode; increase the inlet
temperature in heating mode
In ventilation mode, the tempera-
ture cannot be set
Replace the remote control batter-
ies
Reactivate the electric current
The conditioner will switch off at
the time set
The conditioner will switch on au-
tomatically at the time set and the
relative indicator will switch off
Aim the remote control signal
transmitter directly towards the ap-
pliance infra-red receiver and then
press the ON/OFF key twice (P5)