Descargar Imprimir esta página

Mennekes AMTRON 4You 300 11 Manual De Instrucciones Y De Instalación página 54

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91
3
Product description
3.1
Main features
General
n Mode 3 charging according to IEC 61851
n Plug and socket according to IEC 62196
n Max. charging power (AMTRON® 4You 300 11):
11 kW
n Max. charging power (AMTRON® 4You 300 22):
22 kW
n Connection: single phase / three phase
n Max. charging power configurable by qualified
electrician
n LED status display
n Switching charging modes using button on the
wallbox
n Energy-saving mode for reduced standby con-
sumption
n Permanently connected charging cable type 2
(7.5 m)
n Integrated cable hanger
n Replaceable front cover
Authorisation options
n Autostart (without authorisation)
n RFID (ISO / IEC 14443 A / B)
compatible with MIFARE classic and MIFARE
DESFire
Options for local load management
n Reduction of the charging current using an ex-
ternal switching contact (downgrade input)
n Reduction of the charging current in case of un-
even phase load (unbalanced load limitation)
n Solar charging through an upstream, external
energy meter
n Single-phase and three-phase solar char-
ging for charging powers of 1.4 - 11 kW, in-
cluding dynamic phase switchover
(AMTRON® 4You 300 11)
6
n Solar charging for charging powers of 4.2 -
 22 kW (AMTRON® 4You 300 22)
n Local blackout protection through the connec-
tion of an external Modbus RTU energy meter
Options for connecting to an external energy
management system (EMS)
n Via Modbus RTU
Integrated protective devices
n Residual current device must be installed up-
stream
n Miniature circuit breaker must be installed up-
stream
n DC residual current monitoring > 6 mA in ac-
cordance with IEC 62955
n Switching output for controlling an external
shunt release, in order to disconnect the char-
ging point voltage from the mains in case of a
fault (welded load contact, welding detection)
3.2
Rating plate
The rating plate contains all important product data.
u Observe the name plate on your product. The
rating plate is located on the left-hand side of
the bottom section of the housing.
1
2
3
4
9
5
10
6
11
7
8
Fig. 1: Product rating plate (sample)

Publicidad