Technical data
Max. charging power [kW]
Rated current I
 [A]
nA
Rated current of a charging point
Mode 3 I
[A]
nC
Max. back-up fuse [A]
Conditional rated short-circuit
current I
[kA]
cc
AMTRON® 4You 300 11, AMTRON® 4You 300 22
Connection
Nominal voltage U
[V] AC ±10 %
N
Nominal frequency f
 [Hz]
N
Nominal insulation voltage U
Nominal impulse withstand voltage U
Nominal diversity factor RDF
Types of system earthing
EMC classification
Protection class
IP rating
Overvoltage category
Mechanical impact protection
Contamination rating
Installation
Stationary / movable
Use (according to IEC 61439-7)
External design
Dimensions H x W x D [mm]
Weight [kg]
Standard
The specific standards according to which the product was tested can be found in the declaration of con-
formity for the product. The declaration of conformity can be found on our website in the download section
for the selected product.
AMTRON® 4You 300 11
11
16
16
20
1.1
[V]
i
[kV]
imp
AMTRON® 4You 300 22
22
32
32
40
1.8
single phase / three phase
230 / 400
50
500
4
1
TN / TT (IT under certain conditions)
A+B
I
IP 54
III
IK10
3
Outdoor or indoor
Stationary
AEVCS
Wall mounted
402 x 226 x 168
5.1 / 6.3
IEC 61851, IEC 61439-7
EN
11

Publicidad