Descargar Imprimir esta página

Mennekes AMTRON 4You 300 11 Manual De Instrucciones Y De Instalación página 57

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 91
Response of
Meaning
the LEDs (de-
fault colour
setting)
A vehicle is connected to the
product. Authorisation has oc-
curred.
Charging process paused. Pos-
sible faults are, for example:
n There is not enough energy to
charge in the "Solar charging"
Pulsates
or "Solar-assisted charging"
blue.
modes.
n The operating temperature was
temporarily exceeded.
n Blackout protection was tem-
porarily activated.
n The limit value for unbalanced
load was temporarily ex-
ceeded.
n The charging current of the
downgrade input is configured
to 0 A and active.
n A command was received from
the energy management sys-
tem (current setting 0 A).
n Communication with the energy
meter or energy management
system has been lost. The as-
sociated charging current (fall-
back charging current) is con-
figured to 0 A.
In "Standby" mode, the colour is preset to blue (de-
fault colour setting). The colour can be changed to
green by a qualified electrician.
Energy-saving mode for reduced standby consump-
tion:
In "Standby" mode, the product can switch to en-
ergy-saving mode after 10 minutes. The energy
consumption of the product is reduced. The en-
ergy-saving mode is configurable and is enabled in
the delivery state. The energy-saving mode is
ended by an interaction with the product (e.g: plug-
ging in the charging cable, authorisation). The LED
status indicator does not light up in the energy-sav-
ing mode.
Charging
Response of
Meaning
the LEDs (de-
fault colour
setting)
The vehicle is charging.
Lights up
green.
All requirements for charging a
vehicle are met. The charging pro-
cess is paused due to vehicle
feedback or was terminated by
the vehicle.
Pulsates
green.
In "Charging" mode, the colour is preset to green
(default colour setting). The colour can be changed
to blue by a qualified electrician.
Fault
Response of
Meaning
the LEDs
n There is a fault that is prevent-
ing the vehicle from charging.
The fault can only be rectified
by a qualified electrician.
n The product is in teach-in mode
for a new master RFID card.
The DIP switches 1, 2 and 3 on
Lights up red.
bank S2 are set to "ON".
EN
9

Publicidad

loading