100304 - 22-kW HOME STANDBY GENERATOR WITH AXIS CONTROLLER
The RED icon will be lit if the engine was operating above or below
its preset speed limits. These limits are factory set to protect the
HSB and the circuits connected to the generator output circuits.
When this fault occurs, the HSB will shut down, light the RED icon,
shut down and re-start will be disabled. The exterior warning LED
on the back of the HSB enclosure will be activated and lit.
If this failure occurs, contact Champion or your Authorized
Champion Dealer. The RED icon will remain lit until the failure has
been corrected, the HSB will not attempt to transfer or run.
Line Over Voltage
The RED icon will be lit if the HSB generator output power exceeds
preset limits of 257 VAC.
When this fault occurs, the HSB will light the RED icon, shut down
and re-start will be disabled. The exterior warning LED on the
back of the HSB enclosure will be activated and lit. Check and
adjust AVR. Set Voltage to 240 VAC.
Line Under Voltage
The RED icon will be lit if the HSB Generator output power is
below preset limits.
When this fault occurs, the HSB will light the RED icon, shut down
and re-start will be disabled. The exterior warning LED on the
back of the HSB enclosure will be activated and lit. Check and
adjust AVR. Set Voltage to 240 VAC.
Low Battery
The RED icon will be lit if the battery voltage falls below 21.0
volts for at least 5 seconds while the engine is running. If the
battery voltage rises above 22 volts, the icon will turn off. Battery
voltage is NOT monitored when the engine is cranking, just when
®
the engine is running. If the RED icon comes on it will not shut
the HSB off, it will remain lit until the battery condition meets the
required output.
When the icon remains lit, the battery charging should be checked
and the condition of the batteries. Follow the FAULT CODE RESET
instructions to clear the fault after service.
Requires Maintenance
The RED icon will be lit if the HSB generator is ready for
maintenance.
The maintenance hour meter counts from 100 hours to 0. You
need to reset when the hour meter reaches 0. Refer to the
scheduled maintenance chart.
Refer to "Resetting the maintenance hour meter" for instructions
after performing maintenance.
fAULT PROTECTION
In all cases when the icon is RED, this is an indicator that the
HSB has registered a fault and must be corrected. Only the "LOW
BATTERY" and "MAINTENANCE" icons will not latch out or shut
down the HSB. ALL other RED icon faults will latch out, shut down,
disable starting and light the RED icon on the aXis Controller
the exterior warning LED on the backside of the HSB.
APPROXIMATE ENGINE STARTER CRANk CYCLE TIMES
10 seconds ON
10 seconds OFF
(5 Cycles Total)
If the HSB fails to start, the "OVER CRANK" icon will be lit on the
aXis Controller
and the exterior warning LED on the backside of
®
the HSB.
fAULT CODE RESET
In the event a fault has occurred push OFF button to reset then
AUTO button to re-arm.
All faults should be taken seriously and corrected before reset
process is performed.
19
GENERAL INfORMATION
WARNING
and
®