Descargar Imprimir esta página

Champion Global Power Equipment 100304 Manual Del Operador página 28

Generador doméstico de reserva de 22-kw con axis controller
Ocultar thumbs Ver también para 100304:

Publicidad

Idiomas disponibles

Idiomas disponibles

100304 - 22-kW HOME STANDBY GENERATOR WITH AXIS CONTROLLER
Turning Off the Generator
If you need to shut off the generator when it is running, put the
aXis Controller
in the OFF position. This will shut off the engine.
®
With the aXis Controller
in the OFF position, the generator will
®
not start, even if there is loss of utility power.
MAINTENANCE
Before performing maintenance procedures, review SAFETY
section starting on page 9.
Ensure that the ATS and Engine Switches are in the OFF position
before performing any maintenance or cleaning.
Scheduled Maintenance Chart
First 5 Hours of Operation
Change engine oil and filter - Every 100 hours oil
and oil filter change are required
Check exterior warning LED
Inspect and clean enclosure louvers
Check engine oil level
Inspect fuel lines and connections
Inspect and clean battery terminals
Every 2 Years or 100 Hours of Operation
Change engine oil and filter when maintenance
light comes on
Inspect and clean engine air cleaner
Inspect engine spark plug
Reset maintenance hour meter every 100 hours
Complete inspection of generator, engine tune-up,
and valve lash check/adjustment
* Monthly or 24 hours of continuous operation
** Service sooner if operating in high ambient temperatures or a dusty and dirty
environment.
*** Maintenance should be performed by your service dealer.
Weekly
Monthly
√*
√**
√**
√***
®
Spark Plug Specifications
OEM Type ....................................................K7RTC
Replacement Type
.................
Gap
................................
Oil filter Specifications
OEM Type
................................
Replacement Type
....................
Engine Oil
ENGINE OIL REQUIREMENTS
Use American Petroleum Institute (API) Service Class SN or better.
Do not use special additives.
The recommended oil type for typical use is 5W-30 full
synthetic oil. However, using the listed conventional oils
shown in the "Recommended Engine Oil Type" chart may be
used for typical use.
If running generator in extreme temperatures, refer to the
"Recommended Engine Oil Type" chart.
5W-30
°F
-20
0
°C
-28.9
-17.8
-6.7
CHECkING THE ENGINE OIL LEVEL
Check the oil level daily when the generator is running for an
extended period of time.
1. If the generator is running during a utility outage, turn off all
household loads.
2. Put the aXis Controller
28
MAINTENANCE
NGK BKR7ES-11 or equivalent
0.024-0.035 in. (0.6-0.88 mm)
101766 / 717.153000.02
Fram PH3600 or equivalent
NOTICE
Recommended Engine Oil Type
10W-30
10W-40
5W-30 Full Synthetic
20
40
60
80
4.4
15.6
26.7
Ambient temperature
in the OFF position.
®
100
120
37.8
48.9