5. DESCRIPTIONS OF FUNCTIONS AND PARAMETERS
DE
EN
IT
Fan blade anti-
pinch function
ES
Top cover anti-
FR
pinch function
Voltage protection
NL
FI
DK
SE
Opening size
Thickness of
mounting wall
Power
Voltage
Current
Working noise
Max. ventilation
IP rating
Temperature
adjustment in
AUTO mode
Please note: Technical data may change due to further technical development.
Safety Protection Function
In case of any abnormal resistance when the fan blade of VanVent is rotating,
the fan blade will stop after being blocked, and cannot work normally until its
rotation is confirmed normal.
In case of any abnormal resistance during the lifting and lowering of the top
cover of VanVent, the top cover will stop immediately and cannot work nor-
mally until problem is removed.
When the input voltage of the VanVent ventilating fan is smaller than 9V or
higher than 16V, the VanVent ventilating fan does not work and is under volt-
age protection to prevent the vehicle battery from feedback or the VanVent
ventilating fan from being damaged.
Operating Parameters
400mm×400mm
27-80mm
Full load power: 20W+4W (max. wind speed and full lighting)
Normal voltage: 12V, working voltage: 9-16V (VanVent does not work when
the voltage is smaller than 9V or greater than 16V)
Gear 4 by default: ≤0.25A, full-load maximum current ≤1.6A, locked-rotor
maximum current ≤2.0A
Air outlet noise of Gear 4 by default of VanVent ≤ 29dB, air inlet noise
≤32dB;
Air outlet noise of Gear 10 ≤47dB, air inlet noise ≤53dB;
3,000 m³/hour
IPX4
Default temperature of control panel: 26°C (non-adjustable); range of adjust-
able temperature in remote control: -2°C ~ 40°C
CARBEST VanVent | 318028/318029
18

Publicidad

loading

Este manual también es adecuado para:

318028318029