Descargar Imprimir esta página

Parkside PMRA 20-Li B2 Traduccion Del Manual De Instrucciones Originale página 49

Traducción del manual de instrucciones original

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 140
2. Press the charging unit (22) down so
that it is fi rmly seated in the baseplate.
3. Fix the charging unit (22) from below
to the baseplate (21) with the four en-
closed screws (19).
Positioning the charging
station
Course for laying line of boundary
wire
160 cm (63 inches) minimum
distance
200 cm (78.74 inches) mini-
mum distance to wall
200 cm (78.74 inches)
minimum distance to next curve
100 cm (39.37 inches)
minimum distance to next curve
We recommend installing a roof for
the charging station (17) to protect
it from weather damage.
1. Choose a level position for the charg-
ing station (17) near a power outlet
with at least 2 m distance from the
boundary wire to the front and 1 m to
the rear.
Do not fi x the charging station
until you have laid and connect-
ed the boundary wire. Please refer to
"Fixing the charging station" for this.
• The charging station may be inclined
max. 8 cm to the rear and max. 2 cm
to the front.
• Remove any unevenness under the
charging station. The charging station
must never sag.
• Make sure there is suffi cient distance to
ponds, pools and steps.
Laying the boundary wire
Lay the boundary wire (11) around the
lawn area to be worked by the lawn mow-
er. You can do this as follows:
- Stake out the lawn area. Fasten the
boundary wire (11) with the hooks
(13) (above ground).
- Stake out the hooks at a maximum dis-
tance of 1 m. Use additional hooks if
the ground is uneven.
- Bury the boundary wire (11) in the
ground (max. 5 cm deep).
The lawn mower crosses over the
boundary wire by about 20 -
30 cm before it turns around and searches
for a new path. Install the boundary wire
accordingly to prevent damage.
For the initial installation, we recom-
mend marking out the boundary
wire (11) with the hooks (13) in case cor-
rections need to be made at a later date.
The mower works perfectly with a
boundary wire length of up to
200 m. Do not use a longer boundary
wire.
• The lawn area must be bordered as a
single enclosed area.
Course for laying line of bound-
ary wire
• Any parallel boundary wires (11) in-
stalled at a distance of at least 10 cm
are identifi ed as an obstacle by the
lawn mower and are evaded.
equal to or greater than 10 cm
(3.94 inches)
• Any parallel boundary wires (11) at a
distance of 5 mm or less are not detect-
ed by the lawn mower and are passed
over.
GB MT
49

Publicidad