ELECTRICAL CONNECTIONS

The monophase power supply line must have a switch with fuses.
For the electrical connections (line and thermostats), follow the at-
tached wiring diagram. To carry out the connection of the burner to
the power supply line proceed as follows:
-
Unscrew the 4 screws (1) in figure 1.
Remove the lid to access the burner's electrical panel.
-
Loosen screws (2) to remove the cable float plate (3),
pass the two 7 and 4 pole plugs through the hole in figure 2.
-
Reposition the cable float plate as in figure 3.
Turn the cam (4) so that the float exerts sufficient pressure on
the two cables, then tighten the screws that fasten the cable
float. Finally, connect the two 7 and 4 pole plugs (see figure 4).
The housings for the cables for the 7 and 4 pole plugs
!
are for Ø 9.5-10 mm and Ø 8.5-9 mm cable respectively,
this is to ensure the protection rating of IP 44 (Standard
IEC EN 60529) for the electrical panel.
-
To reclose the electrical panel lid, tighten the 4 screws (1) with
adequate torque to ensure the correct seal.
Only professionally qualified technicians may open the
!
burner electrical panel.