Storage System Temperature Sensor Connection Process - Ingeteam INGECON SUN STORAGE 1Play Manual De Instalacion Y Uso

Ocultar thumbs Ver también para INGECON SUN STORAGE 1Play:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Ingeteam

12.3. Storage system temperature sensor connection process

To connect the temperature sensor:
1.
Loosen the corresponding packing gland (see Section "2.7. Description of cable inlets"), remove the cap
and pass the sensor cable through it.
2.
Connect the wiring to terminal J76 PT-100 BAT, as indicated in the above figure, respecting the wiring
colors. The colors of the wires to connect to each terminal appear on the screen-printed electronic card
(R: red, R: red, W: white).
3.
Correctly tighten the packing glands to prevent losses to the protection class, verifying that the wiring is
not taut. Check that the connection is tight.
38
Connecting the storage system temperature sensor
ABH2013IQM01_C- Installation and Operation Manual