6 .4 .5
Evaluation of measurement sheet for checking sensors
Column
Line
1 and 2
1 and 2
3 to 6
Compare the
following:
1 with 2
3
3 with 6
4 with 5
4
3
6 .5

Faults

6 .5 .1
Fault or information messages
Description / message
"Unit outside tolerance".
"Measurement path
interrupted".
"2 parallel measurement
paths interrupted".
"Problem with data
transmission to sensor"
displayed briefly on monitor.
"Problem with data
transmission to sensor"
constantly displayed
on monitor.
"Measurement box
not accessible" briefly
displayed on monitor.
"Measurement box not
accessible" constantly
displayed on monitor.
Robert Bosch GmbH
Action
If the signs are different, subtract the lower measured value from the higher value and enter
the result in column 3. Enter the sign of the higher value in column 3.
If the signs are the same, add the measured values together and enter the result with sign in
column 3.
If the signs are the same, subtract the low measured value from the high value and enter the
result in column 3. If the higher measured value is in column 1, the sign is adopted. If the
higher measured value is in column 2, the sign changes.
If the signs are different, add the measured values together and enter the result in column 3.
Enter the sign from column 1 in column 3.
If the signs are different, add the measured values together and enter the result in column 4.
If the signs are the same, subtract the lower measured value from the higher value and enter
the result in column 4.
If the signs are different, subtract the lower measured value from the higher value and enter
the result in column 4.
If the signs are the same, add the measured values together and enter the result in column 4.
The values in column 4 should not be higher than 3'. If they are, measurement errors have been
made, e.g. changes to vehicle or quick-action clamps.
The measurement must be repeated.
The measured values in column 3 must not be higher than 6'. In the event of a greater
difference, the unit must be re-adjusted. The Service department should then be consulted.
Possible cause
Mechanical damage to sensor,
sensor incorrectly adjusted.
Obstacle between opposing
cameras of sensors.
Vehicle with spoiler or lowered chassis.
Sensors fitted in wrong order.
Search for new communication paths
for data transmission to sensors.
"C" key not pressed prior to measurement.
Sensor not activated.
System number (radio channel) incorrectly set.
Sensor not charged (radio operation).
Sensor not connected (cable operation).
Link with communication processor in
measurement box being re-established.
No link between computer and communication
processor (measurement box).
Incorrect mains voltage.
Program crash.
Communication processor defective.
Program description | FWA 43xx / 44xx | 43
FWA 43xx / 44xx | 43
Remedy / action
Re-adjust (calibrate) unit.
Inform customer service.
Remove obstruction.
Switch sensors on again.
Press "C" key.
Special accessories: Use
appropriate spoiler adapter.
Fit sensors correctly (refer to 4.8).
Ignore fault message.
Press "C" key.
Activate sensor and press C key on unit.
Set system number (radio channel) for
each sensor (refer to Online Help).
Charge sensor.
Check connector and cable to sensor.
Select and set different system number
(radio channel) (refer to Online Help).
Heed notes on radio operation in Section
2.4, test with cable connection.
Ignore fault message.
Check wiring between computer and
communication processor (in measurement box).
Set mains voltage selector switch in
measurement box to correct voltage.
Inform customer service.
Unplug mains connector and plug
in again after 10 seconds.