Pressure Sensor Calibration - Suunto OBSERVER TT Guía De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 134
setup mode. The top field will display "SET" momentarily and then change to "UNI".
NOTE: Setup mode will automatically exit if left idle for more than one minute.
2. Press the [SELECT] button for 2 seconds to view the first setting. You will see the first
unit flashing.
WARNING: If you perform a short press of the [SELECT] button while in the "UNI"
setting mode, you will switch to Pressure Sensor Calibration. Refer to the next section
for more details.
3. Press the [SELECT] button to move to the unit you want to change. You can change
the flashing unit. The units are in the following order: m/ft, m/min / ft/min, hPa/inHg,
ºC/ºF.
4. Press the [ON OFF] or [QUICK] button to toggle between the metric and imperial
settings.
5. To confirm the setting(s), press the [MODE] button.
6. To exit the setup process, press the [MODE] button again.

1.11 PRESSURE SENSOR CALIBRATION

WARNING: This is a FACTORY CALIBRATION SETTING. Do not enter this mode.
If you enter this mode in error, exit immesdiately by pressing the [MODE] or [SELECT]
button to return to the "UNI" setting mode. Normally there is no need to alter the
calibration.
If the Pressure Setting Calibration has been altered, you can return the factory setting.
Proceed as follows: In the calibration setting mode, scroll the barometric pressure value
up or down until text "dEF" appears. This is the factory setting. Then exit by pressing
[MODE].
12

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Observer lttObserver stObserver srObserver sr black

Tabla de contenido