EN
Spare parts and consumables
11.3
Bacterial filter, complete, disposable
Medication container, container and lid
Corrugated hose 300 mm
Corrugated hose 1200 mm
Nebulizer chamber, complete
Nebulizer chamber lid
Nebulizer chamber incl. label
Quartz module with thermal switch
Hinged arm
Holding-down device, stainless steel
Bottle holder, stainless steel
Caution, risk of device defect!
The use of non-original spare parts can cause personal injury or functional failure. For this
reason, only original spare parts or parts that comply with the interface description must
be used.
11.4 Interface description
All devices or accessories combined with the ultrasonic nebulizer must be listed in 11.2 and 11.3 and meet the
requirements of the following interface description in accordance with Zweckbestimmung under the intended
operating conditions. Only accessories and consumables suitable for the specific application, which have with CE
symbol and possess the characteristics defined in the interface description, are approved. The authorized personnel is
responsible for configuration of the overall system and functionality checks.
12 Disposal
At the end of its life span, the ultrasonic nebulizer must be properly disposed of. Take care to separate the material
accurately. The device and accessories do not contain any hazardous materials; the device component materials can be
fully recycled.
This product falls under the scope of EC Directive 2002/96/EC (Waste Electrical and Electronic Equipment Directive).
The distributor or an authorized dealer takes back the device at the end of its use period for a fee. Disposal via the
municipal collection points for waste electrical and electronic equipment is not allowed. For more information on legal
disposal, please contact your authorized specialist dealer.
Outside of the European Economic Community
For disposal of this product, the applicable national regulations regarding disposal and handling of waste electronic
equipment must be complied with.
13 Technical data
13.1 Ambient conditions
During operation:
Temperature
Temperature when using the hose
heater with heatable hose
Relative humidity
During storage:
Temperature
Relative humidity
Performance data
13.2
Voltage
Fuses
Power consumption:
96200-xxx_00 GA USV Tropic 2.0_20160229.docx
KRÖMKER
2150-00-0-001-00
2002-02-2-900
2002-02-1-928
2002-02-1-932
2002-02-6-902
2002-00-1-902
2002-02-1-602
2002-02-1-685
5003-24-0-000
3151-02-1-000
3101-02-1-000
10 °C to 35°C
10 °C to 30 °C
0 to 90 % relative humidity, non-condensing
-20 °C to 70 °C
0 to 90 % relative humidity, non-condensing
110V/ 127V/ 230V
50 - 60Hz
IEC 60127-2/ III T1L 250V, 2 pieces
DRÄGER
MP01790
MP00006
MP03307
MP03306
MP03304
MP03313
MP03310