6
SP_us.book Page 78 Wednesday, May 30, 2012 1:30 AM
6
800S (800 gpm) requerimiento de potencia de la bomba (P2)
800S (800 gpm) pump power requirement (P2)
P2
P2
[kW]
[hp]
140
100
135
130
95
125
90
120
85
115
110
80
105
75
100
70
95
90
65
85
60
80
75
55
70
50
65
45
60
78
0
100
200
300
400
0
25
50
75
500
600
700
800
100
125
150
175
800S
60 Hz, SF 1.15
ISO 9906 Annex A
-5 (125 hp)
-5-A (125 hp)
-5-AA (125 hp)
-4 (100 hp)
-4-A (100 hp)
-4-AA (100 hp)
900
1000
1100
1200
Q [US GPM]
200
225
Q [m³/h]
SP
SP