IND560 PDX Installation Manual
Main PCB
The IND560 PDX terminal's main printed circuit board (PCB) provides the
POWERCELL PDX scale interface.
The main board also contains two electrically isolated serial ports – COM1
(providing RS-232, RS-422, or RS-485 communication) and COM 4 (providing
RS-232 communication only). These ports are bidirectional and can be configured
for various functions such as demand output, remote display, SICS host
communications, continuous output, ASCII input, CTPZ, report printing, and totals
printing, or connection to ARM100 remote I/O modules.
The main board also contains the AC power input connections, front panel
keyboard interface and bus connectors for the option boards.
Options
The following options are available for the IND560 PDX:
Discrete I/O
•
Ethernet/Dual Serial Ports Option
•
Ethernet/USB/Serial Ports Option
•
Programmable Logic Control (PLC) interfaces, including:
•
Fill-560 advanced filling/blending/dosing application software
•
Drive-560 simple In/Out vehicle weighing application software
•
COM-560 legacy communication protocol software
•
TaskExpert™ application development software
•
Various brackets for wall and column mounting of the harsh enclosure
•
Discrete I/O
The discrete I/O interface options include both internal and remote I/O.
The internal version is available with dry-contact relay outputs. The relay
•
contacts will switch up to 30 volts DC or 250 volts AC. The inputs are switch
selectable as either active (for simple pushbutton control) or passive (for
connection to PLCs or other devices that supply their own power for the I/O).
The remote I/O is supported with the ARM100 remote module that provides dry-
•
contact outputs. The inputs are passive on the ARM100. An external 10 to 32
VDC power supply is required to operate the ARM100.
1-10
Internal, high-level discrete I/O and remote discrete I/O via ARM100 module
Analog Output
Allen-Bradley
EtherNet/IP™
PROFIBUS
DP
RIO
DeviceNet™
Modbus TCP